Punching Shear Check Using ADAPT PT Unbalanced Moments
Punching Shear Check Using ADAPT PT Unbalanced Moments Extracting Unbalanced Moment from ADAPT 1. Analyze the strip using EFM (Equivalent Frame Method) in ADAPT PT and click on the report which will...
View ArticleDesign for Seismic Tie Beams
Per ACI 318-08 section 21.12.3.2 – “Grade beams designed to act as horizontal ties between pile caps or footings shall be proportioned such that the smallest cross-sectional dimension shall be equal to...
View ArticleLocal Axes in ETABS
Vertical Line Objects. For vertical line objects the local axes have the following default orientation: Local axis 1 is along the line object. The positive local 1 axis is in the same direction as the...
View ArticleEarthquake Load Calculation (Base Shear Method)
The 3-story standard office building is located in Los Angeles situated on stiff soil. The structure of the building is steel special moment frame. All moment-resisting frames are located at the...
View ArticleAssigning Pier and Spandrel Labeling in ETABS
Wall piers are typically assigned in the model to the wall over height of floor (as in Figure d below). Often, it is more appropriate to assign the pier to the height of wall adjacent to opening...
View ArticleDuctility In Structures
Have you ever participated in a marathon? Or have you ever practiced for one? The only way you can finish a marathon is high stamina and a constant comfortable pace. If you run too fast, the energy in...
View ArticleEarthquakes and Energy Dissipation
In this blog post, I will try to explain in simplest words possible as to what happens to a building during an earthquake. Imagine this: You are travelling in a car which I am driving. I applied a...
View ArticleResponse Spectrum Analysis
"Response" is what an object, living or nonliving, gives to a certain situation. It can be passive response or active response but it doesn't matter. What matters is how the buildings respond to...
View ArticleHow to Modify Wall Stiffness to Transfer Load Directly to Support
Modification of wall stifness to transfer load from top of the wall directly to the supporting beam. This video was created as an answer to a customer question. Details Language English Duration...
View ArticleAnalysis and Design of One Way and Two Way Slab in STAAD.Pro
STAAD gives the reinforcement for a concrete slab modeled as a plate. For this you have to assign some thickness to the plate. Next go to Concrete design > Commands > Design slab/element. Select...
View ArticleCalculation of Steel Structures in SAP2000 and ETABS (Part II)
Details Language Russian Duration 80 Mins Format .MP4 Size 345 Mb . Download Code Calculation of Steel Structures in SAP2000 and ETABS (Part II) The post Calculation of Steel Structures in...
View ArticleUnder-Reinforced Beam
To understand the importance and necessity of a doubly reinforced beam, first we should look at a singly reinforced beam. A beam when loaded can possibly suffer through two different type of failure:...
View ArticleOutriggers in Tall Buildings
Image 1: Eccentricity between center of rigidity (Center of Resistance) and center of mass causing an unbalanced moment which causes instability in your body and it is hard to balance it out. Image...
View ArticleBuilding Analysis and Design in ETABS
Details Language English Duration 46 Mins Format .MP4 Size 343 Mb . Download Code Building Analysis and Design in ETABS The post Building Analysis and Design in ETABS appeared first on...
View ArticleElastic Beam Calculations Handbook
The Elastic Beam Calculations Handbook presents a mathematically rigorous treatment of beams based on elastic theory written at a technical level that is as simple as can be achieved without losing...
View ArticleCIA Z48-2002 (CD) Precast Concrete Handbook
This Handbook is the first book on the market specifically devoted to all aspects of Australian precast concrete construction including design, specification, manufacture and installation. The Handbook...
View ArticleRAM Connection CONNECT Edition 11.00.01.208
Bentley Systems Incorporated, the leading company dedicated to providing comprehensive software solutions for sustaining infrastructure, has released the 11.00.01.208 version of RAM Connection CONNECT...
View ArticleAutodesk AutoCAD Civil 3D 2017 Add-Ins Exclusive to Subscription Customers
Autodesk Inc., a world leader in 3D design software for entertainment, natural resources, manufacturing, engineering, construction, and civil infrastructure, has presented Add-Ins and Extensions...
View ArticleRAM Elements V8i SS4 13.04.01.208
Bentley Systems Inc., the leading company dedicated to providing comprehensive software solutions for sustaining infrastructure, has released the V8i (SELECTSeries 4) 13.04.01.208 version of RAM...
View ArticleRAM Concept CONNECT Edition V6 Update 2
Bentley Systems Incorporated, the leading company dedicated to providing comprehensive software solutions for sustaining infrastructure, has released the Update 2 (version 06.02.00.14) version of RAM...
View Article